Fluoride Removal Water Filtration System
Couldn't load pickup availability
Features
- Timer Control Valves
- Heavy duty composite fiberglass tanks
- High Flow Distributor
- All brass, motor driven control valve with fully adjustable backwash cycles
- Self-adjusting backwash controller
- Flow controller to limit backwash flow
- Engineered for commercial & industrial use
Benefits
- Reduced water consumption
- Engineered for commercial & industrial use
Add-Ons*
- Metered Control Valve
- Metered to backwash based on demand
- Backwash bypass
- 3200NT Controller
- NXT Upgrade Controller
- Duplex parallel, twin alternating, triplex (progressive)
- Optional skid mounting for tanks
*If you are interested in our available add-ons, please call to have them added to your system.
Fluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg/l. Concentrations above 5 mg/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg/l.
How It Works
Crystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.
Eagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.
- Good adsorption of various heavy metals
- Produced from aged bones for better efficiency
- Maintains alkalinity in adsorbate
An Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride. If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.
Service Flow Rate ( GPM) | ||||||||
---|---|---|---|---|---|---|---|---|
GPM | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 205 |
Model No. | CQE-CO-02075 |
CQE-CO-02076 |
CQE-CO-02077 | CQE-CO-02078 | CQE-CO-02079 | CQE-CO-02080 | CQE-CO-02081 |
CQE-CO-02082 |
Electronic Control Valve | 2510 | 2815 | 2815 | 2900 | 2900 | 3900 | 3900 | 3900 |
Pipe Size | 1" | 1.5" | 1.5" | 2" | 2" | 3" | 3" | 3" |
PSI Range | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 |
Smart Multimedia |
3 ft3 | 4 ft3 | 7 ft3 | 10 ft3 | 15 ft3 | 20 ft3 | 30 ft3 | 40 ft3 |
Quartz (lbs.) | 30 | 80 | 100 | 200 | 400 | 500 | 700 | 900 |
Mineral Tank Size (in.) | 14x65 | 16x65 | 21x62 | 24x72 | 30x72 | 36x72 | 42x72 | 48x72 |
Service flow (gpm) | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 205 |
Peak flow (gpm) | 22 | 41 | 60 | 95 | 140 | 250 | 270 | 280 |
Backwash flow (gpm) | 5 | 7 | 12 | 15 | 25 | 35 | 50 | 65 |
Space Required (in.) (WxDxH) | 15x16x75 | 17x18x75 | 23x24x84 | 24x24x95 | 32x32x95 | 40x48x95 | 46x54x95 | 52x60x95 |
Consumables | ||||||||
---|---|---|---|---|---|---|---|---|
GPM | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 205 |
Model No. | CQE-CO-02075 | CQE-CO-02076 | CQE-CO-02077 | CQE-CO-02078 | CQE-CO-02079 | CQE-CO-02080 | CQE-CO-02081 | CQE-CO-02082 |
Eagle Fluoride Resin |
3 ft3 | 4 ft3 | 7 ft3 | 10 ft3 | 15 ft3 | 20 ft3 | 30 ft3 | 40 ft3 |
Quartz (lbs.) | 30 | 80 | 100 | 200 | 400 | 500 | 700 | 900 |
Filtration Media Information |
||
---|---|---|
Product Data Sheet |
Safety Data Sheet |
|
Calcium GAC | Calcium GAC Product Data Sheet |
Calcium GAC Safety Data Sheet |
Aluminum Oxide Fluoride | Aluminum Oxide Fluoride Removal Product Data Sheet | Aluminum Oxide Fluoride Removal Safety Data Sheet |
ERA 6500 & 9500 | ERA 6500 & 9500 Product Data Sheet |
ERA 6500 & 9500 Safety Data Sheet |
Ion Exchange | Ion Exchange Resin Product Data Sheet |
Ion Exchange Resin Safety Data Sheet |
Installation Instructions |
||||||||
---|---|---|---|---|---|---|---|---|
SYS. INSTALLATION & OPERATION GUIDE |
||||||||
GPM | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 205 |
Model No. | CQE-CO-02075 | CQE-CO-02076 | CQE-CO-02077 | CQE-CO-02078 | CQE-CO-02079 | CQE-CO-02080 | CQE-CO-02081 | CQE-CO-02082 |
Electronic Valve |
2510 Control Head Manual |
2815 Control Head Manual |
2815 Control Head Manual |
2900 Control Head Manual |
2900 Control Head Manual |
3900 Control Head Manual |
3900 Control Head Manual |
3900 Control Head Manual |
Mechanical Upflow Valve | 1" |
1.5" |
1.5" |
1.5" |
2" |
N/A |
N/A |
N/A |
Mechanical Down Flow/ Backwashable Valve |
1" | 1.5" | 1.5" | 1.5" | 2" | N/A | N/A | N/A |
Schematics | Review | Review | Review | Review | Review | Review | Review | Review |
Schematic Samples | ||
---|---|---|
Single Standard Configuration |
Double Standard Configuration |
Triple Standard Configuration |
Calcium GAC Product Data Sheet
Aluminum Oxide Fluoride Removal Product Data Sheet
Aluminum Oxide Fluoride Removal Safety Data Sheet
ERA 6500 & 9500 Product Data Sheet
ERA 6500 & 9500 Safety Data Sheet
General Commercial Tank Manual
20 Cu 185 GPM Fluoride Removal Schematic
Features
- Timer Control Valves
- Heavy duty composite fiberglass tanks
- High Flow Distributor
- All brass, motor driven control valve with fully adjustable backwash cycles
- Self-adjusting backwash controller
- Flow controller to limit backwash flow
- Engineered for commercial & industrial use
Benefits
- Reduced water consumption
- Engineered for commercial & industrial use
Add-Ons*
- Metered Control Valve
- Metered to backwash based on demand
- Backwash bypass
- 3200NT Controller
- NXT Upgrade Controller
- Duplex parallel, twin alternating, triplex (progressive)
- Optional skid mounting for tanks
*If you are interested in our available add-ons, please call to have them added to your system.
Fluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg/l. Concentrations above 5 mg/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg/l.
How It Works
Crystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.
Eagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.
- Good adsorption of various heavy metals
- Produced from aged bones for better efficiency
- Maintains alkalinity in adsorbate
An Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride. If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.
Service Flow Rate ( GPM) | ||||||||
---|---|---|---|---|---|---|---|---|
GPM | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 205 |
Model No. | CQE-CO-02075 |
CQE-CO-02076 |
CQE-CO-02077 | CQE-CO-02078 | CQE-CO-02079 | CQE-CO-02080 | CQE-CO-02081 |
CQE-CO-02082 |
Electronic Control Valve | 2510 | 2815 | 2815 | 2900 | 2900 | 3900 | 3900 | 3900 |
Pipe Size | 1" | 1.5" | 1.5" | 2" | 2" | 3" | 3" | 3" |
PSI Range | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 | 35-60 |
Smart Multimedia |
3 ft3 | 4 ft3 | 7 ft3 | 10 ft3 | 15 ft3 | 20 ft3 | 30 ft3 | 40 ft3 |
Quartz (lbs.) | 30 | 80 | 100 | 200 | 400 | 500 | 700 | 900 |
Mineral Tank Size (in.) | 14x65 | 16x65 | 21x62 | 24x72 | 30x72 | 36x72 | 42x72 | 48x72 |
Service flow (gpm) | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 205 |
Peak flow (gpm) | 22 | 41 | 60 | 95 | 140 | 250 | 270 | 280 |
Backwash flow (gpm) | 5 | 7 | 12 | 15 | 25 | 35 | 50 | 65 |
Space Required (in.) (WxDxH) | 15x16x75 | 17x18x75 | 23x24x84 | 24x24x95 | 32x32x95 | 40x48x95 | 46x54x95 | 52x60x95 |
Consumables | ||||||||
---|---|---|---|---|---|---|---|---|
GPM | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 205 |
Model No. | CQE-CO-02075 | CQE-CO-02076 | CQE-CO-02077 | CQE-CO-02078 | CQE-CO-02079 | CQE-CO-02080 | CQE-CO-02081 | CQE-CO-02082 |
Eagle Fluoride Resin |
3 ft3 | 4 ft3 | 7 ft3 | 10 ft3 | 15 ft3 | 20 ft3 | 30 ft3 | 40 ft3 |
Quartz (lbs.) | 30 | 80 | 100 | 200 | 400 | 500 | 700 | 900 |
Filtration Media Information |
||
---|---|---|
Product Data Sheet |
Safety Data Sheet |
|
Calcium GAC | Calcium GAC Product Data Sheet |
Calcium GAC Safety Data Sheet |
Aluminum Oxide Fluoride | Aluminum Oxide Fluoride Removal Product Data Sheet | Aluminum Oxide Fluoride Removal Safety Data Sheet |
ERA 6500 & 9500 | ERA 6500 & 9500 Product Data Sheet |
ERA 6500 & 9500 Safety Data Sheet |
Ion Exchange | Ion Exchange Resin Product Data Sheet |
Ion Exchange Resin Safety Data Sheet |
Installation Instructions |
||||||||
---|---|---|---|---|---|---|---|---|
SYS. INSTALLATION & OPERATION GUIDE |
||||||||
GPM | 15 | 20 | 35 | 60 | 75 | 185 | 200 | 205 |
Model No. | CQE-CO-02075 | CQE-CO-02076 | CQE-CO-02077 | CQE-CO-02078 | CQE-CO-02079 | CQE-CO-02080 | CQE-CO-02081 | CQE-CO-02082 |
Electronic Valve |
2510 Control Head Manual |
2815 Control Head Manual |
2815 Control Head Manual |
2900 Control Head Manual |
2900 Control Head Manual |
3900 Control Head Manual |
3900 Control Head Manual |
3900 Control Head Manual |
Mechanical Upflow Valve | 1" |
1.5" |
1.5" |
1.5" |
2" |
N/A |
N/A |
N/A |
Mechanical Down Flow/ Backwashable Valve |
1" | 1.5" | 1.5" | 1.5" | 2" | N/A | N/A | N/A |
Schematics | Review | Review | Review | Review | Review | Review | Review | Review |
Schematic Samples | ||
---|---|---|
Single Standard Configuration |
Double Standard Configuration |
Triple Standard Configuration |
Calcium GAC Product Data Sheet
Aluminum Oxide Fluoride Removal Product Data Sheet
Aluminum Oxide Fluoride Removal Safety Data Sheet
ERA 6500 & 9500 Product Data Sheet
ERA 6500 & 9500 Safety Data Sheet
General Commercial Tank Manual
20 Cu 185 GPM Fluoride Removal Schematic