Collection: Industrial Brackish Reverse Osmosis

30,000 - 180,000
Gallons Per Day

Brackish water or briny water is water that has more salinity than fresh water, but not as much as seawater. It may result from mixing of seawater with fresh water, as in estuaries, or it may occur in brackish fossil aquifers. The word comes from the Middle Dutch root "brak". Certain human activities can produce brackish water, in particular civil engineering projects such as dikes and the flooding of coastal marshland to produce brackish water pools for freshwater prawn farming. Brackish water is also the primary waste product of the salinity gradient power process. Because brackish water is hostile to the growth of most terrestrial plant species, without appropriate management it is damaging to the environment.

VIPER Series Industrial Reverse Osmosis Systems are engineered to treat demanding feed water conditions like low temperature or a high content of dissolved solids. Designed for robust applications requiring a high pressure pump (up to 400 psi) the Viper™ Industrial Series Reverse Osmosis Systems are ideally suited for brackish water with total dissolved solids (TDS) in the range of 5000 to 10,000 ppm.

Brackish Water Reverse Osmosis Reclamation

Image may not exactly resemble end product.
For Illustrative purposes only.

 


3280 With Optional
Concentrate Recycle Loop

The models of the Viper Industrial Series range in capacity from 20 to 125 gallons per minute (30,000 to 180,000 per day). Using high efficiency 8- inch reverse osmosis elements with 10% greater membrane surface area, Viper Industrial Series systems are able to significantly reduce the TDS in both municipal and well water sources while producing higher volumes of permeate. Low energy brackish membranes are available for cold temperature applications and high rejection brackish membranes are available for high TDS applications.

The Viper Industrial Series models feature a pre-programmed computer controller, motorized feed valve, TDS probes, and panel-mounted pressure and flow instrumentation. The larger models include digital indication flow and VFD motor control. Stainless steel components are used for the vertical multistage pump, cartridge filter housing, high pressure piping and valves and the ports of the FPR pressure vessels. High pressure hose is employed for ease of maintenance.


Standard Features

  • Low Energy or High Rejection Brackish Membranes
    (depending on the application)
  • Fiberglass Membrane Housings with Stainless Steel Ports
  • 5 Micron Sediment Pre-Filter
  • Multi-Cartridge Stainless Steel Cartridge Housing
  • Permeate and Concentrate Digital Paddle Wheels
  • Pre-and Post-Filter Pressure Gauges
  • Pump Pressure and Concentrate Pressure Gauges
  • Feed and Permeate TDS Meters
  • Low and High Pressure Shut-Off Switch
  • Auto Feed Shut-Off

Design and specifications are subject to change without notice.

  • Stainless Steel Globe Valves
  • Motor Feed Valve
  • Vertical Stainless Steel Multistage Pump
  • Powder Coated Carbon Steel Frame
  • Stainless Steel (High Pressure Side) Piping Components
  • Sch8- PVC Piping (Low Pressure Side)
  • Chemical Feed Power Outlet
  • Chemical Feed Port
  • Clean-In-Place (CIP) Ports
  • Permeate Sample Ports
  • 460VAC 3PH 60HZ

Options & Upgrades

  • S-200 Computer Controller***
  • VFD***
  • Programmable Logic Controller (PLC) w/ Touch Screen
  • Permeate and Concentrate Digital Paddle Wheels***
  • Motorized Feed Valve***
  • Concentrate Recycle Loop w/ Flow Meter
 *Standard on Models 2280-5280
 **Standard on Models 3480-6480
 ***Option available for Models 2280-5280. Standard on larger models.
  • Permeate Divert
  • Permeate Flush
  • pH and/ or ORP Sensor
  • Chemical Feed System
  • Clean-In-Place (CIP) Ports
  • Clean-In-Place Skid-Mounted System


All dimensions are given in inches



Systems Specifications

CQE-BW-01974 CQE-BW-01975 CQE-BW-01976 CQE-BW-01977
System Capacity
gpd(m3d)
28,000 (109) 43,200 (163) 57,600 (218) 75,000 (284)
Configuration Single Pass Single Pass Single Pass Single Pass
Feed Water
Source***
TDS<10,000 ppm TDS<10,000 ppm TDS<10,000 ppm TDS<10,000 ppm
Standard
Recovery Rate
15% 65% 60% 67%
Recovery w/ Concentrate
Recycle gpm
75% 75% 75% 75%
Rejection and Flow Rates
Nominal Salt Rejection % 97-99% 97-99% 97-99% 97-99%
Permeate Flow* gpm (lpm) 20 (75.6) 30 (113.4) 40 (151.2) 50 (189.0)
Minimum Concentrate Flow gpm (lpm) 14 (53) 14 (53) 14 (53) 14 (53)
Connections
Feed Inch 2 FNPT 2 FNPT 2 FNPT 2 FNPT
Permeate Inch 1 ½” FNPT 1 ½” FNPT 2"FNPT 2" FNPT
Concentrate Inch 1 ¼ “ FNPT 1 ¼ “ FNPT 1 ¼ “ FNPT 1 ¼ “ FNPT
Clean-In-Place
Port Inch
1 ½” FNPT 1 ½” FNPT 1 ½” FNPT 1 ½” FNPT
Chemical Feed
Port Inch
½” NPT ½” NPT ½” NPT ½” NPT
Membranes
Membrane Per Vessel 2 2 2 2
Membrane Quantity 4 6 8 10
Membrane Size 8040 8040 8040 8040
Vessels
Vessel Array 1:1 1:1:1 2:1:1 2:1:1:1
Vessel Quantity 2 3 4 5
Pump
Pump Type Vertical Multistage Centrifugal Vertical Multistage Centrifugal Vertical Multistage Centrifugal Vertical Multistage Centrifugal
Motor HP (KW) 15 (11) 15 (11) 25 (19) 25 (19)
Electric
Standard Voltage 460V, 60Hz, 3Ph 460V, 60Hz, 3Ph 460V, 60Hz, 3Ph 460V, 60Hz, 3Ph
Systems Dimensions**
L X W X H Inch (Cm) 112 x 35 x 85
(284 x 89 x 216)
112 x 35 x 85
(284 x 89 x 216)
112 x 35 x 85
(284 x 89 x 216)
112 x 35 x 85
(284 x 89 x 216)
Weight Lb. (Kg) 1,285/ 583 1,435/ 651 1,585/719 1,735/787
 

Price

Please Call
(800) 934-0051
Please Call
(800) 934-0051
Please Call
(800) 934-0051
Please Call
(800) 934-0051
 

Systems Specifications

CQE-BW-01978 CQE-BW-01979 CQE-BW-01980 CQE-BW-01981
System Capacity
gpd(m3d)
90,000 (341) 120,200 (454) 150,000 (545) 180,000 (681)
Configuration Single Pass Single Pass Single Pass Single Pass
Feed Water
Source***
TDS<10,000 ppm TDS<10,000 ppm TDS<10,000 ppm TDS<10,000 ppm
Standard
Recovery Rate
75% 75% 75% 75%
Recovery w/ Concentrate
Recycle gpm
NA NA NA NA
Rejection and Flow Rates
Nominal Salt Rejection % 97-99% 97-99% 97-99% 97-99%
Permeate Flow* gpm (lpm) 60 (226.8) 80 (302.4) 100 (378.0) 125 (472.5)
Minimum Concentrate Flow gpm (lpm) 14 (53) 14 (53) 14 (53) 14 (53)
Connections
Feed Inch 3” FNPT 3” FNPT 3” FNPT 3” FNPT
Permeate Inch 2 ½” FNPT 2 ½” FNPT 3” FNPT 3" FNPT
Concentrate Inch 1 ½” FNPT 1 ½” FNPT 2" FNPT 2" FNPT
Clean-In-Place
Port Inch
2” FNPT 2” FNPT 2” FNPT 2” FNPT
Chemical Feed
Port Inch
½” NPT ½” NPT ½” NPT ½” NPT
Membranes
Membrane Per Vessel 4 4 4 4
Membrane Quantity 12 16 20 24
Membrane Size 8040 8040 8040 8040
Vessels
Vessel Array 2:1 2:1:1 3:1:1 3:2:1
Vessel Quantity 3 4 5 6
Pump
Pump Type Vertical Multistage Centrifugal Vertical Multistage Centrifugal Vertical Multistage Centrifugal Vertical Multistage Centrifugal
Motor HP (KW) 25 (19) 40 (30) 40 (30) 50
Electric
Standard Voltage 460V, 60Hz, 3Ph 460V, 60Hz, 3Ph 460V, 60Hz, 3Ph 460V, 60Hz, 3Ph
Systems Dimensions**
L X W X H Inch (Cm) 194 x 41 x 86
(493 x 104 x 218)
194 x 41 x 86
(493 x 104 x 218)
194 x 41 x 86
(493 x 104 x 218)
194 x 41 x 86
(493 x 104 x 218)
Weight Lb. (Kg) 2,005/ 910 2,275/ 1032 2,645/ 1200 2,910/ 1320

 