8 Products
Collection: Industrial Brackish Reverse Osmosis
30,000 - 180,000
|
![]() Image may not exactly resemble end product. |
|
|
![]() 3280 With Optional |
The models of the Viper Industrial Series range in capacity from 20 to 125 gallons per minute (30,000 to 180,000 per day). Using high efficiency 8- inch reverse osmosis elements with 10% greater membrane surface area, Viper Industrial Series systems are able to significantly reduce the TDS in both municipal and well water sources while producing higher volumes of permeate. Low energy brackish membranes are available for cold temperature applications and high rejection brackish membranes are available for high TDS applications. The Viper Industrial Series models feature a pre-programmed computer controller, motorized feed valve, TDS probes, and panel-mounted pressure and flow instrumentation. The larger models include digital indication flow and VFD motor control. Stainless steel components are used for the vertical multistage pump, cartridge filter housing, high pressure piping and valves and the ports of the FPR pressure vessels. High pressure hose is employed for ease of maintenance. |
Standard Features |
|
Design and specifications are subject to change without notice. |
|
Options & Upgrades |
|
**Standard on Models 3480-6480 ***Option available for Models 2280-5280. Standard on larger models. |
|
![]() ![]() |
All dimensions are given in inches ![]() |
![]() ![]() |
![]() |
Systems Specifications |
||||||
CQE-BW-01974 | CQE-BW-01975 | CQE-BW-01976 | CQE-BW-01977 | |||
System Capacity gpd(m3d) |
28,000 (109) | 43,200 (163) | 57,600 (218) | 75,000 (284) | ||
Configuration | Single Pass | Single Pass | Single Pass | Single Pass | ||
Feed Water Source*** |
TDS<10,000 ppm | TDS<10,000 ppm | TDS<10,000 ppm | TDS<10,000 ppm | ||
Standard Recovery Rate |
15% | 65% | 60% | 67% | ||
Recovery w/ Concentrate Recycle gpm |
75% | 75% | 75% | 75% | ||
Rejection and Flow Rates | ||||||
Nominal Salt Rejection % | 97-99% | 97-99% | 97-99% | 97-99% | ||
Permeate Flow* gpm (lpm) | 20 (75.6) | 30 (113.4) | 40 (151.2) | 50 (189.0) | ||
Minimum Concentrate Flow gpm (lpm) | 14 (53) | 14 (53) | 14 (53) | 14 (53) | ||
Connections | ||||||
Feed Inch | 2 FNPT | 2 FNPT | 2 FNPT | 2 FNPT | ||
Permeate Inch | 1 ½” FNPT | 1 ½” FNPT | 2"FNPT | 2" FNPT | ||
Concentrate Inch | 1 ¼ “ FNPT | 1 ¼ “ FNPT | 1 ¼ “ FNPT | 1 ¼ “ FNPT | ||
Clean-In-Place Port Inch |
1 ½” FNPT | 1 ½” FNPT | 1 ½” FNPT | 1 ½” FNPT | ||
Chemical Feed Port Inch |
½” NPT | ½” NPT | ½” NPT | ½” NPT | ||
Membranes | ||||||
Membrane Per Vessel | 2 | 2 | 2 | 2 | ||
Membrane Quantity | 4 | 6 | 8 | 10 | ||
Membrane Size | 8040 | 8040 | 8040 | 8040 | ||
Vessels | ||||||
Vessel Array | 1:1 | 1:1:1 | 2:1:1 | 2:1:1:1 | ||
Vessel Quantity | 2 | 3 | 4 | 5 | ||
Pump | ||||||
Pump Type | Vertical Multistage Centrifugal | Vertical Multistage Centrifugal | Vertical Multistage Centrifugal | Vertical Multistage Centrifugal | ||
Motor HP (KW) | 15 (11) | 15 (11) | 25 (19) | 25 (19) | ||
Electric | ||||||
Standard Voltage | 460V, 60Hz, 3Ph | 460V, 60Hz, 3Ph | 460V, 60Hz, 3Ph | 460V, 60Hz, 3Ph | ||
Systems Dimensions** | ||||||
L X W X H Inch (Cm) | 112 x 35 x 85 (284 x 89 x 216) |
112 x 35 x 85 (284 x 89 x 216) |
112 x 35 x 85 (284 x 89 x 216) |
112 x 35 x 85 (284 x 89 x 216) |
||
Weight Lb. (Kg) | 1,285/ 583 | 1,435/ 651 | 1,585/719 | 1,735/787 | ||
Price |
Please Call (800) 934-0051 |
Please Call (800) 934-0051 |
Please Call (800) 934-0051 |
Please Call (800) 934-0051 |
||
Systems Specifications |
||||||
CQE-BW-01978 | CQE-BW-01979 | CQE-BW-01980 | CQE-BW-01981 | |||
System Capacity gpd(m3d) |
90,000 (341) | 120,200 (454) | 150,000 (545) | 180,000 (681) | ||
Configuration | Single Pass | Single Pass | Single Pass | Single Pass | ||
Feed Water Source*** |
TDS<10,000 ppm | TDS<10,000 ppm | TDS<10,000 ppm | TDS<10,000 ppm | ||
Standard Recovery Rate |
75% | 75% | 75% | 75% | ||
Recovery w/ Concentrate Recycle gpm |
NA | NA | NA | NA | ||
Rejection and Flow Rates | ||||||
Nominal Salt Rejection % | 97-99% | 97-99% | 97-99% | 97-99% | ||
Permeate Flow* gpm (lpm) | 60 (226.8) | 80 (302.4) | 100 (378.0) | 125 (472.5) | ||
Minimum Concentrate Flow gpm (lpm) | 14 (53) | 14 (53) | 14 (53) | 14 (53) | ||
Connections | ||||||
Feed Inch | 3” FNPT | 3” FNPT | 3” FNPT | 3” FNPT | ||
Permeate Inch | 2 ½” FNPT | 2 ½” FNPT | 3” FNPT | 3" FNPT | ||
Concentrate Inch | 1 ½” FNPT | 1 ½” FNPT | 2" FNPT | 2" FNPT | ||
Clean-In-Place Port Inch |
2” FNPT | 2” FNPT | 2” FNPT | 2” FNPT | ||
Chemical Feed Port Inch |
½” NPT | ½” NPT | ½” NPT | ½” NPT | ||
Membranes | ||||||
Membrane Per Vessel | 4 | 4 | 4 | 4 | ||
Membrane Quantity | 12 | 16 | 20 | 24 | ||
Membrane Size | 8040 | 8040 | 8040 | 8040 | ||
Vessels | ||||||
Vessel Array | 2:1 | 2:1:1 | 3:1:1 | 3:2:1 | ||
Vessel Quantity | 3 | 4 | 5 | 6 | ||
Pump | ||||||
Pump Type | Vertical Multistage Centrifugal | Vertical Multistage Centrifugal | Vertical Multistage Centrifugal | Vertical Multistage Centrifugal | ||
Motor HP (KW) | 25 (19) | 40 (30) | 40 (30) | 50 | ||
Electric | ||||||
Standard Voltage | 460V, 60Hz, 3Ph | 460V, 60Hz, 3Ph | 460V, 60Hz, 3Ph | 460V, 60Hz, 3Ph | ||
Systems Dimensions** | ||||||
L X W X H Inch (Cm) | 194 x 41 x 86 (493 x 104 x 218) |
194 x 41 x 86 (493 x 104 x 218) |
194 x 41 x 86 (493 x 104 x 218) |
194 x 41 x 86 (493 x 104 x 218) |
||
Weight Lb. (Kg) | 2,005/ 910 | 2,275/ 1032 | 2,645/ 1200 | 2,910/ 1320 |
To inquire about the right water filtration system for your organization, please email commercial@crystalquest.com or call 1-800-934-0051