$110.00 SKU CQE-PS-00401

220/240V Up Float Switch

You save $16.50

Regular price $110.00 Sale price $93.50

$110.00

Fills a tank automatically. 16(8)A, IP68, counterweight included.

  • Shop Pay
  • Apple Pay
  • Google Pay
  • Visa
  • Mastercard
  • American Express
Shipping

Free shipping on orders over $150

Residential addresses in the lower 48 US states. Excludes business addresses, commercial and industrial systems (which ship by freight), and filter media sold by the bag or cubic foot.

Order by 3:00 PM Eastern on a business day and most filters, cartridges and smaller items leave our facility that same day. Standard residential systems ship within 1 to 2 business days, and whole house, custom and specialty systems typically within 3. So far in 2026, 95% of our orders have shipped within one business day and 99% within five (based on an internal review of our order records).

Once shipped, standard delivery typically arrives in 3 days to the Southeast, Northeast and Southwest, and in 4 days to the Midwest and the West. Need it sooner? UPS 2nd Day Air and Next Day Air are available at checkout for eligible products. Systems that ship by freight can take longer and may need a delivery appointment.

60-day returns

You have 60 days from delivery to ask for a return. Unopened or unused products get a full refund of the product price with no restocking fee. Opened and used products have a 30% restocking fee, or up to 50% if they come back with visible damage or wear. You pay shipping both ways, every return needs a return approval number from us first, and custom systems cannot be returned.

Lifetime support

Our team answers questions about products, orders, installation, troubleshooting and replacement parts.

Phone: (770) 951-5600 or (800) 934-0051

Email: help@crystalquest.com. Typical responses within 24 hours (M-F).

Live chat during business hours

Hours: Monday to Friday, 9:00 AM to 5:00 PM Eastern. We observe U.S. federal holidays.

110/120V Up Float Switch - Parts - Crystal Quest®

How do I install it?

In the box: the float switch with its attached cable, the counterweight with its fixing ring, and the installation guide.

Good to know

  • Size the pump by its running amps: up to 8 A it can be switched directly; above that use a relay or contactor.
  • Connect the cable in a dry junction box above the water. The cable cannot be repaired.
  • Up fills a tank; Down stops a delivery pump before the tank runs dry. This is the Up version.
  1. Turn off power to the pump circuit before you start.
  2. Peel the plastic ring off the counterweight and slide it onto the cable. Push the cable through the counterweight from its cone end and press it firmly onto the ring at the height where you want the switch to work.
  3. Fix the cable to a support in the tank so the float hangs free and cannot touch the tank wall, the pump or the inlet.
  4. Set the free cable between the counterweight and the float. More free cable gives a wider gap between the on and off levels.
  5. Bring the cable out of the tank through a cable gland and connect it in a dry junction box above the water. The cable end must never be submerged.
  6. Wire the blue wire and the common for this job and insulate the brown wire. For a pump over 8 A, wire the float to the coil of a relay or contactor rated for the pump.
  7. Ground the pump, restore power and raise and lower the water to check that the pump starts and stops at the levels you want.

Fills a tank automatically. 16(8)A, IP68, counterweight included.

Read more
SKU CQE-PS-00401
Edit selections

Overview

The 220/240V Up float switch fills a water storage tank automatically: it starts the pump when the water drops and stops it when the tank is full. It is a tethered cable float switch rated 16(8)A at 250 V AC, sealed to IP68 and supplied with a counterweight, so it fits storage tanks, cisterns, booster pump systems and pump pits.

How a cable float switch works

The float hangs on its own cable, held at a set height by the counterweight. When the water rises, the float tips up; when the water falls, it hangs down. At a set angle the switch inside changes over and opens or closes the pump circuit. The free cable between the counterweight and the float sets how far apart the on and off levels are.

What the Up float switch does

Fill a tank (pump up). The pump runs while the water is low and stops when the tank is full. Wire the blue wire and the common and keep the brown wire insulated, as shown in the wiring guide.

Matching the switch to your pump

Check the running amps on the pump's nameplate. If the pump draws 8 A or less, the float switch can switch it directly. If it draws more than 8 A, which includes most 1 HP pumps on 120 V, let the float switch control a relay, magnetic contactor or pump control panel rated for the pump. The float then carries only the small coil current and lasts much longer.

Where it is used

  • A well pump or transfer pump that fills a water storage tank
  • A reverse osmosis system that fills an atmospheric storage tank and should stop when the tank is full
  • Rainwater or cistern top-up from another source

Frequently asked questions

How does a float switch work?

A float switch rides on the water surface. As the level changes, the float tilts, and a switch inside it opens or closes the circuit that runs the pump. A cable float switch like this one swings on its own cable, so it needs no rods or brackets.

What is the difference between the Up and Down float switch?

Up fills a tank: the pump runs while the water is low and stops when the tank is full. Down empties a tank or protects a delivery pump: the pump runs while there is water and stops when the level falls. The switch has changeover contacts; Up uses the blue wire and the common, Down uses the brown wire and the common.

Can this float switch run a 1 HP pump?

Not directly on 120 V. Its motor rating is 8 A, and most 1 HP pumps draw more than that on 120 V. Use the float switch to control a relay or magnetic contactor rated for the pump.

What does 16(8)A mean?

The switch carries up to 16 A on a resistive load such as a heater, and up to 8 A on a motor load such as a pump. Size it by the motor figure for pumps.

How do I set the on and off levels?

Fix the counterweight at the height where you want the switch to work, then adjust the free cable between the counterweight and the float. A longer free cable gives a bigger gap between the on and off levels and fewer pump starts.

Can I extend the cable?

Connect the cable end to your own wiring inside a dry junction box above the water line. Do not cut, splice or repair the cable inside the tank, and never let the connection sit under water.

What is the maximum water temperature?

131°F (55°C).

Specifications

Part number
CQE-PS-00401
Job
Fill a tank (pump up). The pump runs while the water is low and stops when the tank is full.
For pumps on
220/240V
Switch rating
125/250 V AC, 50/60 Hz
Maximum current
16(8)A: 16 A resistive, 8 A motor load
Pump connection
Directly for pumps that draw up to 8 A running; above that through a relay or magnetic contactor
Switch
Changeover contacts: common, normally open and normally closed
Wires
3: brown, blue and yellow-green (or black) common. This job uses the blue wire and the common
Protection
IP68, sealed for submersion
Maximum water temperature
131°F (55°C)
Float type
Tethered cable float with counterweight
Switching level
Set by the counterweight position and the free cable length

Parts & Components

Parts included

  • Float switch with sealed float and attached 3 conductor cable
  • Counterweight with fixing ring
  • Installation and instruction guide with wiring diagrams

Installation Instructions

  1. Turn off power to the pump circuit before you start.
  2. Peel the plastic ring off the counterweight and slide it onto the cable. Push the cable through the counterweight from its cone end and press it firmly onto the ring at the height where you want the switch to work.
  3. Fix the cable to a support in the tank so the float hangs free and cannot touch the tank wall, the pump or the inlet.
  4. Set the free cable between the counterweight and the float. More free cable gives a wider gap between the on and off levels.
  5. Bring the cable out of the tank through a cable gland and connect it in a dry junction box above the water. The cable end must never be submerged.
  6. Wire the blue wire and the common for this job and insulate the brown wire. For a pump over 8 A, wire the float to the coil of a relay or contactor rated for the pump.
  7. Ground the pump, restore power and raise and lower the water to check that the pump starts and stops at the levels you want.

Product Manual

Review the installation manual

Documents

Reviews