2.5" x 21" Freshwater Reverse Osmosis Membrane
2.5" x 21" Freshwater Reverse Osmosis Membrane
$150.89
Regular price $162.25
SKU CQE-RC-04084
Save $11.36 compared with one-time purchase
A low energy freshwater RO element for 400 to 1,000 GPD whole house and Mid-Flow RO systems.
Read moreCouldn't load pickup availability
Description
Is your whole house RO making less water than it used to, or is the TDS reading on the purified side creeping up? In 400 to 1,000 GPD Crystal Quest systems, the 2.5" x 21" elements do the purifying, so their condition decides how much water you get and how clean it tastes.
The Crystal Quest 2.5" x 21" Freshwater Reverse Osmosis Membrane (CQE-RC-04084, the 2521 element size) is a low-energy, thin-film composite (TFC) element for pre-filtered, dechlorinated municipal or well water. It is the replacement element listed for the 400, 500 and 1,000 GPD Whole House Reverse Osmosis System and the same sizes of the Commercial and Medical Mid-Flow RO Systems.
At a glance
- Counts by system: one for 400 GPD, two for 500 GPD and three for 1,000 GPD on the Whole House RO
- Low-energy freshwater class: for tap and well water under 2,000 ppm TDS, rated at 150 psi operating pressure
- System performance: Crystal Quest whole house RO systems are rated for 98.5% nominal and 96% minimum salt rejection
- Long service life: plan on 2 to 3 years; actual life depends on feed water quality, system configuration and usage
What you are looking at
A 21" spiral-wound element. Leaves of TFC membrane, separated by a mesh feed spacer, wrap around a perforated permeate tube. Feed water travels along the spacer channels; purified water (permeate) passes through the membrane and spirals into the center tube, while the concentrate leaves the far end carrying the rejected minerals. A brine seal on the inlet end seals the element to the housing wall so every gallon passes through it, not around it. It ships in preservative solution with protectors on each end of the permeate tube. The 21" length fits only housings built for it; it is not interchangeable with 2.5" x 14" or 2.5" x 40" elements.
How it purifies water
Pressure against osmosis
Dissolved salts create osmotic pressure that pulls water toward the saltier side of a membrane. The system pump pushes harder than that pull, driving water molecules through the membrane while dissolved ions stay in the feed stream. Crystal Quest rates its whole house RO elements at 150 psi operating pressure.
Why there is a drain line
The concentrate stream sweeps the membrane surface as it flows, which is how an element runs for years instead of clogging like a cartridge. A Crystal Quest RO system sends about 1 gallon to drain for every 1 to 3 gallons of purified water, set to your water chemistry.
Why winter output drops
Colder water passes through the membrane more slowly, and higher TDS raises the osmotic pressure the pump has to beat. Production returns as the water warms; if it does not, check the pre-filters, then rejection and flow.
What it reduces
Primary target: total dissolved solids (TDS): the hardness minerals, sodium, chloride and sulfate behind scale, spotting and salty or mineral taste. Crystal Quest whole house RO systems are rated for 96% minimum and 98.5% nominal salt rejection.
Also held back: any particle that reaches the membrane, microplastics included, is far too large to pass. The pre-filters remove most of them first.
Not designed to handle: free chlorine (0.1 ppm maximum, so remove it upstream), sediment, and iron or manganese above 0.05 ppm. Feed hardness should be under 15 gpg on the 400 GPD system and under 5 gpg on 500 and 1,000 GPD systems; harder water scales the membrane, so soften first. Brackish groundwater and seawater need a brackish or seawater desal element instead.
Why Crystal Quest
- The listed element and count for your Crystal Quest system, straight from our replacement tables.
- Complete specs: operating limits and feed water limits in the Specifications tab.
- Over 1,000,000 people served since 1994. Crystal Quest builds under ISO 9001 quality management, has made water filtration in the USA for over 30 years and offers lifetime support by phone, email or chat.
Where it fits
- Whole House Reverse Osmosis System: 400 GPD (1), 500 GPD (2), 1,000 GPD (3).
- Commercial Mid-Flow and Medical Mid-Flow RO Systems, 500 and 1,000 GPD: use the quantity in your system's replacement table.
- Not this element: the 300 GPD Whole House RO and 200 GPD Low-Flow RO use the 2.5" x 14" element; 750 to 2,500 GPD systems use the 2.5" x 40" element.
RO membranes are not returnable under our refund policy. Confirm the part number on your current element, or call us and we will confirm it with you.
Standard 2521 format
This is a low-energy freshwater element in the standard 2521 (2.5" x 21") format used in 2.5" membrane housings built for 21" elements, including Crystal Quest systems. Crystal Quest rates its whole house RO elements at 150 psi operating pressure, well below what brackish water and seawater elements are built for, so the pump does less work on tap and well water. A shared format name is a good start, not a guarantee: if your system is not a Crystal Quest model, compare the brine seal position, permeate tube ends and flow direction with your current element, or contact us before ordering.
Storage and handling
Each element ships sealed in its bag in a preservative solution. Keep it sealed until you are ready to install it, store it indoors out of direct sunlight, and never let it freeze. Once an element has been installed and wetted, do not let it dry out. If your system will sit idle for a season, Membrane Preservative is used to protect the elements against damage from bacterial growth.
Common questions
Which systems use the 2.5" x 21" element?
The 400, 500 and 1,000 GPD Whole House Reverse Osmosis System, and the 500 and 1,000 GPD Commercial and Medical Mid-Flow RO Systems.
How many elements do I need?
Use the count in your system's replacement table. On the Whole House Reverse Osmosis System it is one for 400 GPD, two for 500 GPD and three for 1,000 GPD.
Should I replace all the elements at once?
Yes. On two- and three-element systems, replacing the full set keeps the elements sharing the load evenly and resets your performance baseline.
How long does a 2521 RO membrane last?
Plan on 2 to 3 years. Actual life depends on feed water quality, system configuration and usage. Good pre-filtration, softening where needed and routine flushing help it reach the full span.
Do I need to flush a new element?
Yes. New elements ship in a preservative solution. Flush for at least 1 hour and discard all permeate and concentrate made during the flush.
Can chlorinated city water go straight to the membrane?
No. The thin-film membrane tolerates no more than 0.1 ppm free chlorine, so the carbon and SMART pre-filters must remove chlorine first. Change them on schedule to protect the element.
Freshwater, brackish or seawater?
This is the freshwater element, for feed water under 2,000 ppm TDS. Choose the class your system and feed water are designed for, and ask Crystal Quest if you are unsure.
Specifications
Specifications for your selection
Single
- SKU
- CQE-RC-04084
- Diameter (width)
- 2.5 in
- Length (height)
- 21.0 in
- Replace every
- 2 to 3 years
Specifications for your selection
Single
- SKU
- CQE-RC-04084
- Diameter (width)
- 2.5 in
- Length (height)
- 21.0 in
- Replace every
- 2 to 3 years
Specifications for your selection
Pack of 2
- SKU
- CQE-RC-04084-2PK
- Diameter (width)
- 2.5 in
- Length (height)
- 21.0 in
- Replace every
- 2 to 3 years
Specifications for your selection
Pack of 4
- SKU
- CQE-RC-04084-4PK
- Diameter (width)
- 2.5 in
- Length (height)
- 21.0 in
- Replace every
- 2 to 3 years
- Membrane type
- Thin-film composite (TFC) reverse osmosis element
- Application
- Freshwater (low energy)
- Element size
- 2.5" x 21" (2521 format)
- Part number
- CQE-RC-04084
- Listed replacement for
- Whole House Reverse Osmosis System 400 GPD (1), 500 GPD (2), 1,000 GPD (3); Commercial and Medical Mid-Flow RO Systems 500 and 1,000 GPD (quantity per system table)
- Feed water
- Pre-filtered and dechlorinated; free chlorine 0.1 ppm maximum
- Rated production
- 400 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water
- Nominal salt rejection
- 99% (96% minimum) at 550 ppm feed, 150 psi, 77°F (25°C), 15% recovery
- Operating pressure
- Rated maximum: 600 psi; suggested operating range: 100 to 150 psi
- Pressure note
- 600 psi is the element's structural limit; low energy elements are designed to make their rated flow at about 150 psi
- Maximum temperature
- 113°F (45°C)
- pH range
- Rated 2 to 11; suggested 5 to 11 for continuous operation; cleaning 2 to 12
- Maximum feed TDS (system)
- Under 2,000 ppm
- Start-up
- Flush at least 1 hour; discard all permeate and concentrate from the flush
- Replacement interval
- 2 to 3 years; actual life depends on feed water quality, system configuration and usage
- Format
- Standard 2521 element; compare brine seal position and tube ends if your system is not a Crystal Quest model
- Storage
- Keep sealed until installation, out of direct sunlight; do not let it freeze, and do not let an installed element dry out
Performance curves
Rated 400 GPD at 77°F (25°C), 150 psi, 550 ppm feed.
Data for Figure 1
| Feed temperature | 100 psi | 125 psi | 150 psi |
|---|---|---|---|
| 40°F (4°C) | 123 | 156 | 189 |
| 50°F (10°C) | 152 | 193 | 234 |
| 60°F (16°C) | 186 | 237 | 287 |
| 70°F (21°C) | 227 | 289 | 350 |
| 77°F (25°C) | 260 | 330 | 400 |
| 85°F (29°C) | 296 | 376 | 456 |
| 95°F (35°C) | 346 | 440 | 533 |
Values in GPD (gallons per day).
Data for Figure 2
| Feed pressure | 50°F (10°C) | 60°F (16°C) | 77°F (25°C) |
|---|---|---|---|
| 25 psi | 29 | 35 | 49 |
| 50 psi | 70 | 86 | 119 |
| 75 psi | 111 | 136 | 190 |
| 100 psi | 152 | 186 | 260 |
| 125 psi | 193 | 237 | 330 |
| 150 psi | 234 | 287 | 400 |
Values in GPD (gallons per day).
Crystal Quest engineering data. Typical values calculated from the element's rated output at standard test conditions; actual output depends on feed water, recovery and element condition.
Element specifications
| Specification | Value |
| Membrane type | Thin-film composite (TFC) reverse osmosis element |
| Application | Freshwater (low energy) |
| Element size | 2.5" x 21" (2521 format) |
| Part number | CQE-RC-04084 |
| Listed replacement for | Whole House Reverse Osmosis System 400 GPD (1), 500 GPD (2), 1,000 GPD (3); Commercial and Medical Mid-Flow RO Systems 500 and 1,000 GPD (quantity per system table) |
| Feed water | Pre-filtered and dechlorinated; free chlorine 0.1 ppm maximum |
| Start-up | Flush at least 1 hour; discard all permeate and concentrate from the flush |
| Service life | 2 to 3 years* |
Element operating limits
| Rated production | 400 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water |
| Nominal salt rejection | 99% (96% minimum) at 550 ppm feed, 150 psi, 77°F (25°C), 15% recovery |
| Operating pressure | Rated maximum: 600 psi; suggested operating range: 100 to 150 psi |
| Maximum temperature | 113°F (45°C) |
| pH range | Rated 2 to 11; suggested 5 to 11 for continuous operation; cleaning 2 to 12 |
| Free chlorine tolerance | 0.1 ppm maximum. Remove chlorine and chloramine before the membrane with carbon pre-filtration (Crystal Quest whole house RO systems include this). |
| Maximum turbidity | 1 NTU |
| Silt density index | Less than 5 SDI |
Feed water limits for the system
| Total dissolved solids | Under 2,000 ppm |
| Hardness | Under 15 gpg (400 GPD); under 5 gpg (500 and 1,000 GPD) |
| Iron and manganese | Under 0.05 ppm each |
| Silica and organics | Under 1 ppm each |
| Free chlorine | None (remove upstream) |
| Feed temperature | 40°F to 105°F |
*Service life is an estimate. Actual life depends on feed water quality, system configuration and usage. System figures are from the Crystal Quest whole house RO manuals; production falls with colder or higher-TDS water. Element ratings are from the element data sheet. The 600 psi rating is the element's structural limit. Low energy elements are designed to make their rated flow at about 150 psi.