High-Flow Reverse Osmosis System 10,000 GPD - 50,000 GPD

SKU: CQE-CO-02036
Regular price $56,009.15
Flow Rate
Rendering loop-subscriptions

Standard Features:

  • Thin Film Composite Membranes
  • Stainless Steel Membrane Housings
  • Centrifugal Pump
  • 9x48 Vessel with .5 Micron Zeolite (Turbidity/ Sediment Removal)
    & Coconut Shell Granulated Activated Carbon
  • Low & High-Pressure Shut-Off Switch
  • Auto Feed Shut-Off
  • Flow Control
  • Feed Pressure Gauges
  • System Pressure Gauges
  • Cleaning Ports
  • Permeate Flowmeter
  • Concentrate Flowmeter
  • Permeate TDS Display
  • Feed TDS Display
  • Heavy Duty Coated Aluminum Frame
  • C-150 Microprocessor Controller
    (standard no ethernet, but optional upgrade)

Benefits:

  • Compact Space Saving
  • Components Easily Accessible
  • Expandable and Lightweight Design
  • Fully Equipped and Customizable
  • Pre-plumbed, wired, and assembled
  • Low Operation Costs
  • Low Maintenance Costs
  • Easily Maintenance and servicing
  • Factory Tested and Preserved
  • CE Compliant
  • 1-Year Limited Warranty
  • Made in the USA

Automatically Controls: 

  • Motorized Actuated Feed Valve
  • Delayed High-Pressure Pump Start-Up
  • Automatic Shut-Down at Tank Full
  • Low or High-Pressure Fault Shut-Down
  • Pre-Treatment Lock-Out
  • Feed Water Flush at Shut-Down
  • High Product TDS Alarm Shutdown

    Upgrades:

    All systems include a standard with a wide range of features. There are various options and upgrades available to accommodate a diverse range of water treatment applications. Listed below is a selection of the most popular upgrades.

    • Stainless-Steel Rotary Vane Pump: Offers a longer lifespan and increase resistance to high TDS feed water and corrosive materials, such as dosing chemical and antiscalants.
    • Concentrate recycle valve: Allows for an increase of RO systems efficiency by recycling back wastewater into the feed stream and increasing the system recovery
    • SWP Digital Dual TDS Controller: Allow for simultaneous monitoring of both feed TDS and permeate TDS levels, helping to monitor the RO system salt rejection and membrane performance.
    • SWP Digital TDS Controller: Allow for monitoring either feed TDS and Permeate TDS levels
    • SWP Digital TDS/Conductivity Controller: Allow for the monitoring of the RO permeate water TDS and conductivity levels, useful in evaluating overall system performance IF Computer Controller with feed flush: Allow for pre-treatment lockout functionality, tank level input, features a convenient LED status display indicator for increase ease of use.
    • C-150 Computer Controller with Feed Flush: Allow for pre-treatment lockout functionality, tank level input, features a convenient LED status display, and alarm function.
    • Chemical Pump Outlet: Provide an integrated power source with the RO system for the connection of a chemical feed pump.
    • Blending Valve: Allows for a mixture of feed water into final RO permeate water to achieve desirable permeate TDS.
    • Permeate Sample Port: Allows for evaluation of individual membrane performance in on RO system and aids in system troubleshooting and maintenance.
    • 240V 50-60Hz or 110V 50-60Hz: Allow for selecting sufficient voltage and hertz use requirement.
    • Single Wood Crate

    Gallons Per Day (GPD) @ 77° F
    GPM 10000 15000 20000 30000 40000 50000
    Model No CQE-CO-02031 CQE-CO-02032 CQE-CO-02033 CQE-CO-02034 CQE-CO-02035 CQE-CO-02036
    Dimensions 49" x 33" x 54" 63" x 39" x 54" 63" x 39" x 54" 41" x 143" x 80" 41" x 143" x 80" 41" x 143" x 80"
    Weight (lbs) 385 400 415 N/A N/A N/A
    Concentrate Re-Circulate Optional Optional Optional Optional Optional Optional
    Auto Flush Optional Optional Optional Optional Included Optional
    Membrane Size 4040 TFC HF1 4040 TFC HF1 4040 TFC HF1 4040 TFC HF1 4040 TFC HF1 4040 TFC HF1
    # of Membranes 6 8 10 14 16 20
    Motor HP 1.5 1.5 3
    3 5
    5
    Voltage* (volts AC) 110/220 110/220 110/220 110/220 110/220 110/220
    Hertz (cycles) 50/60 50/60 50/60 50/60 50/60 50/60
    Feed Connection 1" 1" 1" 2" 2" 2"
    Product Connection 1" 1" 1" 1.5" 1.5" 1.5"
    Waste Connection 1" 1" 1" 1" 1" 1.5"
    Minimum Feed Pressure 45 psi 45 psi 45 psi 45 psi 45 psi 45 psi
    Minimum NaCl - % Rejection 96% 96% 96% 96% 96% 96%
    Minimum Feed (GPM) 14 21 28
    42
    56
    70
    Maximum Hardness (GPG) 15 15 15 15 15 15
    Maximum TDS 2000 ppm 2000 ppm 2000 ppm 2000 ppm 2000 ppm 2000 ppm
    Operating Pressure 150 psi 150 psi 150 psi 150 psi 150 psi 150 psi
    Maximum NaCl - % Rejection 98.5% 98.5% 98.5% 98.5% 98.5% 98.5%
    pH Range 3-11 3-11 3-11 3-11 3-11 3-11

    *All Systems come 110V unless requested otherwise

    The Crystal Quest C-150 Microprocessor Controller has features and options to allow the OEM flexibility to meet many different specifications. The controller has five relay outputs, four dry contact inputs, and two TDS/conductivity inputs. A 2 line by 20 characters LED display provides the operating status of the RO unit along with the water quality, operating hours, and water temperature. This controller is standard for high-flow commercial reverse osmosis systems but has an additional upgrade option for ethernet integration.

     

    The Crystal Quest C-200 Microprocessor Controller is a versatile controller for reverse osmosis systems that offer advanced features and options which make it an exceptional choice for large commercial and industrial reverse osmosis systems.

    The Crystal Quest C-200 Controller has the flexibility to meet many specifications with six (6) switch inputs, five (5) analog inputs, six (6) relay outputs, and two (2) TDS/conductivity inputs. The 4 line by 20 character LCD display provides sensor readings, hours of operation, temperature, alarms, and operating status of the RO system.

     

    Our Stainless Steel Membrane Pressure Vessels enhance system appearance and allow you to take full advantage of the membrane capability. These vessels are considered safer and more reliable than PVC pressure vessels. Designed for continuous long-term use as a pressure vessel for reverse osmosis, nanofiltration, and ultra-filtration elements which are used on typical commercial reverse osmosis water treatment systems at pressures up to 300 PSI. 
    This High Flow Reverses Osmosis system is designed for commercial and industrial applications and is manufactured as a 10,000 GPD Reverse Osmosis, 15,000 GPD Reverse Osmosis, 20,000 GPD Reverse Osmosis, 30,000 GPD Reverse Osmosis, 40,000 GPD Reverse Osmosis, 50,000 GPD Reverse Osmosis,

    Standard Features:

    • Thin Film Composite Membranes
    • Stainless Steel Membrane Housings
    • Centrifugal Pump
    • 9x48 Vessel with .5 Micron Zeolite (Turbidity/ Sediment Removal)
      & Coconut Shell Granulated Activated Carbon
    • Low & High-Pressure Shut-Off Switch
    • Auto Feed Shut-Off
    • Flow Control
    • Feed Pressure Gauges
    • System Pressure Gauges
    • Cleaning Ports
    • Permeate Flowmeter
    • Concentrate Flowmeter
    • Permeate TDS Display
    • Feed TDS Display
    • Heavy Duty Coated Aluminum Frame
    • C-150 Microprocessor Controller
      (standard no ethernet, but optional upgrade)

    Benefits:

    • Compact Space Saving
    • Components Easily Accessible
    • Expandable and Lightweight Design
    • Fully Equipped and Customizable
    • Pre-plumbed, wired, and assembled
    • Low Operation Costs
    • Low Maintenance Costs
    • Easily Maintenance and servicing
    • Factory Tested and Preserved
    • CE Compliant
    • 1-Year Limited Warranty
    • Made in the USA

    Automatically Controls: 

    • Motorized Actuated Feed Valve
    • Delayed High-Pressure Pump Start-Up
    • Automatic Shut-Down at Tank Full
    • Low or High-Pressure Fault Shut-Down
    • Pre-Treatment Lock-Out
    • Feed Water Flush at Shut-Down
    • High Product TDS Alarm Shutdown

      Upgrades:

      All systems include a standard with a wide range of features. There are various options and upgrades available to accommodate a diverse range of water treatment applications. Listed below is a selection of the most popular upgrades.

      • Stainless-Steel Rotary Vane Pump: Offers a longer lifespan and increase resistance to high TDS feed water and corrosive materials, such as dosing chemical and antiscalants.
      • Concentrate recycle valve: Allows for an increase of RO systems efficiency by recycling back wastewater into the feed stream and increasing the system recovery
      • SWP Digital Dual TDS Controller: Allow for simultaneous monitoring of both feed TDS and permeate TDS levels, helping to monitor the RO system salt rejection and membrane performance.
      • SWP Digital TDS Controller: Allow for monitoring either feed TDS and Permeate TDS levels
      • SWP Digital TDS/Conductivity Controller: Allow for the monitoring of the RO permeate water TDS and conductivity levels, useful in evaluating overall system performance IF Computer Controller with feed flush: Allow for pre-treatment lockout functionality, tank level input, features a convenient LED status display indicator for increase ease of use.
      • C-150 Computer Controller with Feed Flush: Allow for pre-treatment lockout functionality, tank level input, features a convenient LED status display, and alarm function.
      • Chemical Pump Outlet: Provide an integrated power source with the RO system for the connection of a chemical feed pump.
      • Blending Valve: Allows for a mixture of feed water into final RO permeate water to achieve desirable permeate TDS.
      • Permeate Sample Port: Allows for evaluation of individual membrane performance in on RO system and aids in system troubleshooting and maintenance.
      • 240V 50-60Hz or 110V 50-60Hz: Allow for selecting sufficient voltage and hertz use requirement.
      • Single Wood Crate

      Gallons Per Day (GPD) @ 77° F
      GPM 10000 15000 20000 30000 40000 50000
      Model No CQE-CO-02031 CQE-CO-02032 CQE-CO-02033 CQE-CO-02034 CQE-CO-02035 CQE-CO-02036
      Dimensions 49" x 33" x 54" 63" x 39" x 54" 63" x 39" x 54" 41" x 143" x 80" 41" x 143" x 80" 41" x 143" x 80"
      Weight (lbs) 385 400 415 N/A N/A N/A
      Concentrate Re-Circulate Optional Optional Optional Optional Optional Optional
      Auto Flush Optional Optional Optional Optional Included Optional
      Membrane Size 4040 TFC HF1 4040 TFC HF1 4040 TFC HF1 4040 TFC HF1 4040 TFC HF1 4040 TFC HF1
      # of Membranes 6 8 10 14 16 20
      Motor HP 1.5 1.5 3
      3 5
      5
      Voltage* (volts AC) 110/220 110/220 110/220 110/220 110/220 110/220
      Hertz (cycles) 50/60 50/60 50/60 50/60 50/60 50/60
      Feed Connection 1" 1" 1" 2" 2" 2"
      Product Connection 1" 1" 1" 1.5" 1.5" 1.5"
      Waste Connection 1" 1" 1" 1" 1" 1.5"
      Minimum Feed Pressure 45 psi 45 psi 45 psi 45 psi 45 psi 45 psi
      Minimum NaCl - % Rejection 96% 96% 96% 96% 96% 96%
      Minimum Feed (GPM) 14 21 28
      42
      56
      70
      Maximum Hardness (GPG) 15 15 15 15 15 15
      Maximum TDS 2000 ppm 2000 ppm 2000 ppm 2000 ppm 2000 ppm 2000 ppm
      Operating Pressure 150 psi 150 psi 150 psi 150 psi 150 psi 150 psi
      Maximum NaCl - % Rejection 98.5% 98.5% 98.5% 98.5% 98.5% 98.5%
      pH Range 3-11 3-11 3-11 3-11 3-11 3-11

      *All Systems come 110V unless requested otherwise

      The Crystal Quest C-150 Microprocessor Controller has features and options to allow the OEM flexibility to meet many different specifications. The controller has five relay outputs, four dry contact inputs, and two TDS/conductivity inputs. A 2 line by 20 characters LED display provides the operating status of the RO unit along with the water quality, operating hours, and water temperature. This controller is standard for high-flow commercial reverse osmosis systems but has an additional upgrade option for ethernet integration.

       

      The Crystal Quest C-200 Microprocessor Controller is a versatile controller for reverse osmosis systems that offer advanced features and options which make it an exceptional choice for large commercial and industrial reverse osmosis systems.

      The Crystal Quest C-200 Controller has the flexibility to meet many specifications with six (6) switch inputs, five (5) analog inputs, six (6) relay outputs, and two (2) TDS/conductivity inputs. The 4 line by 20 character LCD display provides sensor readings, hours of operation, temperature, alarms, and operating status of the RO system.

       

      Our Stainless Steel Membrane Pressure Vessels enhance system appearance and allow you to take full advantage of the membrane capability. These vessels are considered safer and more reliable than PVC pressure vessels. Designed for continuous long-term use as a pressure vessel for reverse osmosis, nanofiltration, and ultra-filtration elements which are used on typical commercial reverse osmosis water treatment systems at pressures up to 300 PSI. 
      This High Flow Reverses Osmosis system is designed for commercial and industrial applications and is manufactured as a 10,000 GPD Reverse Osmosis, 15,000 GPD Reverse Osmosis, 20,000 GPD Reverse Osmosis, 30,000 GPD Reverse Osmosis, 40,000 GPD Reverse Osmosis, 50,000 GPD Reverse Osmosis,

      Customer Reviews

      Be the first to review this product! Write a review
      This is a Sample Product Title
      Was $200.00 Now $100.00